Crowcon Gas-Pro I-Test Unit with Gas Inlet and Gas-Pro Module
- Part Number: IT-GP-11Z-ZB-x
- Categories: Accessories & Spares (Gas Detection)
Crowcon Gas-Pro I-Test Unit with Gas Inlet and Gas-Pro Module
I-Test is Crowcon’s newest solution to test and verify that your Gas-Pro monitors are in a compliant state to carry out your daily work. Bump testing standards are getting tighter in all regions and the need for controlled bump and calibration records is a must. I-Test and the accompanying I-Test Manager software makes this as easy as can be.
When the Gas-Pro or T4 are inserted inserted into I-Test, no button presses are required and I-Test starts testing automatically. A bump test takes less than 1 minute. The test carries out verification that the sensors are responding to a known value of gas, and filters are clear and good for use. It will also ensure the audible and visual alarms are working, giving the user full confidence that they are compliant for site use.
The I-Test is easy to use with no requirements to turn on and off the gas: the design of the demand flow regulator coupled with the I-Test will allow the automatic pull of the correct required amount and concentration of gas. I-Test can also recognise cylinders that are empty or those that have expired allowing full compliance. I-Test stores all bump and calibration results and this can then be interrogated using the I-Test Manager software. This powerful software allows you to carry out exception reporting to see who has and hasn’t carried out their bump or calibrations. I-Test Manager also makes it very easy to print both bump and calibration certificates and any tailored reports you have generated.
Key Features
- Mains powered, or battery back-up – Allows you to use on site, or in field
- Entirely self-contained – No extra computers or equipment required
- Ability to update Gas-Pro configurations – Update to bump test interval or alarm levels of your fleet with ease and no fleet downtime
- Data management – Archive gas level data from detectors long term
- Powerful support software – Makes configuring I-Test to site requirements extremely easy
- I-Test recognises empty or expired cylinders – Avoid using non-compliant bump/calibration gas
- Testing starts automatically when detector is inserted – Minimal user training required
- Ensures the audible and visual alarms are working – Gives the user full confidence that the Gas-Pro is compliant to use
- Battery backup – Testing continues even if the power is out
- Everything is logged – see everything that has been tested and whether it has passed/failed
- Exception reporting – Precise reports flag up who has and hasn’t carried out their bump test or calibration
- Powerful reporting – Need to see which detectors have gone in to alarm in the last month. I-Test manager makes easy work of pulling report summaries together
Have you got a question about this product?
Email us or Call Us on +44 (0)1254 207532