Fireclass 508.031.708 Duo-Cel 2 Wire 2 Zone Panel
- Part Number: 508.031.708
- Categories: Panels (Conventional Fire Alarm Equipment)
Fireclass 508.031.708 Duo-Cel 2 Wire 2 Zone Panel
Based on the technology of our top range panels the Duo-Cel 2W has been adapted from its sister panel (Duo-Cel) to provide a 2 wire solution. The panel has many useful configurable options. No special detectors or callpoints are required, there is just the need to ensure the diode in the detector base is (or changed to) a standard power diode rather than schottky type.
The zone end of line terminator device is also different from the standard panel and consists of a zener diode/resistor combination. The quantity of sounders allowed on a zone depends on detection and sounder type combinations fitted to that zone - see application guide for details.
Key Features:
- 2,4 & 8 Zone 2 wire versions available in an aesthetically pleasing design.
- Uses Fulleon 2 wire sounder (models: Squashni sounder & sounder/beacon base, Symphoni sounder)
- Uses resistor & zener diode EOL device, (no resistor only option as with standard panel)
- Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay
- Easy to install, program and use. Key operated controls access (no ‘user confuser’ codes!)
- Panels can be surface or semi flush mounted and have 20mm cable gland breakouts
- Comprehensive LED indications and user/engineer controls
- Low standby power consumption
- 4 standard sounder circuits 4 & 8 zone, 2 on 2 zone panel (as well as zone sounders)
- Zonal & Alert sounder options configurable
- 1.5A switched mode power supply with temperature compensated battery charging
- Enclosure houses 3.4Ah SLA batteries as standard
- 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only)
Have you got a question about this product?
Email us or Call Us on +44 (0)1254 207532














