Apollo ORB-HT-11006-APO Orbis CS Heat Detector
The Orbis Heat Detector range incorporates six heat detector classes to suit a wide variety of operating conditions in which smoke detectors are unsuitable.
The European Standard EN 54-5 classifies heat detectors to the highest ambient temperature in which they can safely be used without risk of false alarm. The classes are identified by the letters A to C (Class 1 is sub-divided into A1 and A2). In addition to the basic classification, detectors may be identified by a suffix to show that they are rate-of-rise (suffix R) or fixed (static) temperature (suffix S) types.
All heat detectors in the Orbis range are tested as static or rate-of-rise detectors and are classified as A1R, A2S, BR, BS, CR or CS.
Operation
Orbis Heat Detectors have an open-web casing which enables air to flow freely across a thermistor which measures the air temperature every two seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit - the alarm level - has been reached.
In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.
Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.
Key Features:
- Can be used for applications where smoke detectors are unsuitable
- Ideal in environments that are dirty or smoky under normal conditions
- Red flashing LED at StartUp confirms that the device is operating. SensAlert, yellow flashing LED, indicates faulty operation
- FasTest takes just four seconds to test and confirm detectors are functioning correctly