Acorn Fire & Security

Browse Manufacturers

  •  
Credit Cards Accepted
 CFP Standard 2, 4 & 8 Zone

CFP Standard 2, 4 & 8 Zone

Ref: CFP702-4

Keyswitch Option:
Number of Zones:

Price: £118.45

Qty:  

Fully compliant with EN54 parts 2 and 4, the CFP Standard conventional fire alarm panel offers an array of user and installer friendly features. This is the most flexible of the range offering a great selection of functions and settings, allowing easy retro-installation to any existing conventional system, or maximum flexibility on a new installation. This is the best selling version of this panel.
Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4 and 8 zone versions are available, each featuring four conventional sounder circuits, class change and alert inputs, two fire outputs, a fault output and a reset output.A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities.
Comprehensive test and fault finding facilities are also provided on all variants.
In addition to our standard and economy CFP panels, three LPCB approved versions are available. The LPCB stamp of approval is recognised worldwide and demonstrates that the CFP has been tested and certified as being compliant with EN54 parts 2 and 4 by the Loss Prevention Certification Board.

Key Features:

  • Fully compliant with EN54 Parts 2 and 4
  • Standard, Economy and LPCB approved versions
  • Available with 2, 4 or 8 zone circuits
  • Installer-friendly design accommodates easy first fix
    and straightforward maintenance
  • Attractive flush or surface mountable plastic enclosure
  • Four conventional sounder circuits provided on all models
  • Auxiliary remote, auxiliary fire, fault and reset outputs
    ‘Class change' and alert inputs
  • Low quiescent current
  • Intuitive user-friendly interface
  • End of line units included (one per zone)
  • Keyswitch or push button entry (dependent on model
    purchased)
  • Integral 1.5A switch mode PSU
  • Detector and sounder circuits share common negative
    allowing straightforward three-wire retro-installation
  • Ancillary connections provided for up to eight two-wire
    repeaters (one CFP761 network driver card required per
    system) and optional CFP relay boards (ancillary
    connections are not provided on CFP Economy panels)
  • Wide range of engineering functions, as detailed and compared below:-

CFP Economy
 
Zone Test Facility
Fault Diagnostic Facility
No Ancillary Connections
(for System Expansion)

CFP Standard

Zone Delay Facility
Non-Latching Zone Facility
Coincidence (Double Knock) Facility
Zone Test Facility
Fault Diagnostic Facility
Ancillary Connections
(for System Expansion)

CFP LPCB Approved

Zone Delay Facility
Zone Test Facility
Fault Diagnostic Facility
Ancillary Connections
(for System Expansion)

CFP Standard Installation Manual acornfiresecurity.com.pdf Download CFP Standard Installation Manual acornfiresecurity.com.pdf

Contact us about this product