Fully compliant with EN54 parts 2 and 4, the CFP LPCB Approved conventional fire alarm panel offers an array of user and installer friendly features. This is the most cost effective choice of Control Panel when installing to specific LPCB Standards, usually specified by a third party.
Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4 and 8 zone versions are available, each featuring four conventional sounder circuits, class change and alert inputs, two fire outputs, a fault output and a reset output.
A wide range of engineering functions are also provided (depending on the model purchased) including selectable zone delays.Comprehensive test and fault finding facilities are also provided on all variants.
There are three LPCB approved CFP versions available. The LPCB stamp of approval is recognised worldwide and demonstrates that the CFP has been tested and certified as being compliant with EN54 parts 2 and 4 by the Loss Prevention Certification Board.
Key Features:
- Fully compliant with EN54 Parts 2 and 4
- Standard, Economy and LPCB approved versions
- Available with 2, 4 or 8 zone circuits
- Installer-friendly design accommodates easy first fix
and straightforward maintenance - Attractive flush or surface mountable plastic enclosure
- Four conventional sounder circuits provided on all models
- Auxiliary remote, auxiliary fire, fault and reset outputs
‘Class change' and alert inputs - Low quiescent current
- Intuitive user-friendly interface
- End of line units included (one per zone)
- Push button user code entry
- Integral 1.5A switch mode PSU
- Detector and sounder circuits share common negative
allowing straightforward three-wire retro-installation - Ancillary connections provided for up to eight two-wire
repeaters (one CFP761 network driver card required per
system) and optional CFP relay boards (ancillary
connections are not provided on CFP Economy panels) - Wide range of engineering functions, as detailed and compared below:-
CFP Economy
Zone Test Facility
Fault Diagnostic Facility
No Ancillary Connections
(for System Expansion)
CFP Standard
Zone Delay Facility
Non-Latching Zone Facility
Coincidence (Double Knock) Facility
Zone Test Facility
Fault Diagnostic Facility
Ancillary Connections
(for System Expansion)
CFP LPCB Approved
Zone Delay Facility
Zone Test Facility
Fault Diagnostic Facility
Ancillary Connections
(for System Expansion)